If a connection to the app cannot be established after 30 seconds, the Bluetooth symbol goes out and the blood pressure monitor switches off automatically after 5 seconds. show more. Warnings Do not hesitate to contact the manufacturer directly with your concerns and questions. Do not use the blood pressure monitor on newborns, children or pets. Is the blood pressure device also suitable for detecting abnormalities of heart rate? What Are Beurer BM 28 and Omron M3 Devices? This could result in issues such as error messages or the failure of the display/ device. The use of accessories other than those specified or provided by the manufacturer of this device can lead to an increase in electromagnetic emissions or a decrease in the devices electromagnetic immunity; this can result in faulty operation. If using the device for commercial medical purposes, it must be regularly tested for accuracy by appropriate means. Step 4: Select the area of the bodyPress the program button [PROG] to select the body area. knee, hip and shoulder joints), Pain resulting from injury to the musculoskeletal system, Muscle training to increase endurance and/or. In the case of devices with a manometer, there is also parallax error (error in reading the result). If you store the device and cuff, do not place heavy objects on the device and cuff. The temperature of a healthy person is also influenced by the following factors: Beurer tip:Taking the temperature gives a measurement that provides information about a person's current body temperature. Precise instructions for checking accuracy may be requested from the service address. Electrostimulation is a very effective method of stimulating your muscles which results in significant improvements to different muscular qualities, does not involve cardiovascular or mental fatigue and places only minimal strain on your joints and tendons. Source: WHO, 1999 (World Health Organization). In this case, after the measurement, the device will indicate any irregularities in your pulse by displaying the symbol in the display. If the symbol is shown on the display after the measurement has been taken, it should be repeated. Using the blood pressure monitor outside your home environment or whilst on the move (e.g. Blood pressure is always stated in the form of two values: Fluctuations in blood pressure are normal. Air purifiers / air washers / humidifiers, International partners sales and service addresses, Connection to beurer HealthManager possible, approx. Ensure that the cuff is not placed on an arm in which the arteries or veins are undergoing medical treatment, e.g. Calibration is not necessary. Setting the date and timeIt is essential to set the date and time. The blood pressure monitor must not be used in connection with a high-frequency surgical unit. E02: The monitor may have detected movement during the reading. Risk indicatorThe World Health Organization (WHO) has defined the internationally recognised classification for the evaluation of measured blood pressure values listed in the table below: Source: WHO, 1999 (World Health Organization). Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Set the year with the function buttons -/+ and confirm with the memory button, Set the month, day, hour and minutes and confirm each setting with the memory button. Systolic Blood Pressure 140 mmHg 135 mmHg Diastolic Blood Pressure 90 mmHg 85 mmHg Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Ensure the device is at room temperature before measuring. In this situation, the blood pressure must be measured with the stethoscope (Riva-Rocci method) as incorrect results can be obtained with electronic devices. You can find more information about our cookies here: During the blood pressure measurement, blood circulation must not be stopped for an unnecessarily long time. Do not use any cleaning agents or solvents. 2) To select a user memory, press the SET button and select a user from 1 to 4 using the +/- buttons. whilst traveling in a car, ambulance or helicopter, or whilst undertaking physical activity such as playing sport) can influence the measurement accuracy and cause incorrect measurements. Blood pressure may vary between the right and left arm, which may mean that the measured blood pressure values are different. Check that the device packaging has not been tampered with and make sure that all contents are present. 4. Beurer BM 31. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. Do not disassemble, open or crush the batteries. Muscle relaxation for easing muscle tension, Acceleration of muscle regeneration after intense muscle performance (e.g. You will need the beurer HealthManager app for this. Please wait a moment and take your blood pressure again, making sure to not move or talk during the measurement. To carry out a blood pressure measurement, make sure you are sitting upright and comfortably. Target groupIt is designed for self-measurement by adults in the home environment and is suitable for users whose wrist circumference is within the range printed on the cuff. Vivifyhealth Blood Pressure Monitor User Guide The enclosed blood pressure monitor is provided for your use during the Omron Blood Pressure Monitor Manual and Symbols February 7, 2021 February 9, 2021 Posted in Beurer Tags: _pdf , Beurer , Blood Pressure Monitor , BM26 Please note that when inflating, the functions of the limb in question may be impaired. The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. How do I connect my blood pressure monitor to my smartphone? Insert two 1.5 V AAA micro (alkaline type LR03) batteries. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address. Air purifiers / air washers / humidifiers, International partners sales and service addresses, Positioning display (for the right positioning of the blood pressure monitor at heart level), Averaging capability of all saved measurements, Inflation technology -automatic measurement during inflation for quick and convenient measuring, Fully automatic blood pressure and pulse measurement on the wrist, With voice output for the measured values. The wrist blood pressure monitor with inflation technology can be used together with "beurer HealthManager". Here you will find the most frequently asked questions (FAQs) about our Medical products. The serial number is located on the device or in the battery compartment. Our extensive range of blood pressure monitors has the right device for everyone. 1,599.00 MRP 2,380.00. Signs and symbols 4 3. If, however, it is necessary to use the device in the manner stated, this device as well as the other devices must be monitored to ensure they are working properly. The device has been developed with regard to a long useful life. Make sure that the unit is powered off. Electrical muscle stimulation (EMS) is a widespread and generally recognised method which has been used in sports and rehabilitation medicine for years. The gentle electrical impulses increase the production of natural pain relievers in your body, such as endorphins. Omron Blood Pressure (BP) Monitor Error codes E1, E2, E3, E4, E5 - YouTube In this video discussed about E1, E2, E3, E4 and E5 error codes of omron blood pressure (BP) monitor. Ear temperature, measured with an ear thermometer: 36.0 C to 37.8 C. Beurer Blood Pressure Monitor BM 93 User manual manual (232 pages) 4. I give consent until revocation, which can be declared at any time with immediate effect, via the unsubscribe link in the newsletter. Call toll free 1-800-536-0366 or contact info@beurer.com medicines and their administration)! Under no circumstances hold the device and cuff under water, as this can cause liquid to enter and damage the device and cuff. Dispose of them via your electronicsretailer or your local recycling point. This is available in the Apple App Store and from Google Play. Sie haben unter Windows 8/10 Ihr Messgert korrekt mit Ihrem Computer verbunden und fr den Datentransfer aktiviert und erhalten trotzdem eine Fehlermeldung?Um dieses Problem zu beheben, mssen Sie Ihre Treibersoftware aktualisieren. This device is not intended for use by people (including children) with restricted physical, sensory or mental skills or a lack of experience and/or a lack of knowledge unless they are supervised by a person who is responsible for their safety or is instructed by such a person in how to use the device. Before every measurement, relax for about five minutes. In the event of errors, the error message _ appears on the display.Error messages may appear if: In the above cases, you must repeat the measurement. As a result, electrostimulation enables you to stimulate your muscles more than through arbitrary muscle activity. The accuracy of the measurements and service life of the device depend on its careful handling. Accuracy of readings and the instruments service life depend on careful handling. Only by doing so can your measurements with associated date and time be saved and accessed later by you. Relax your arm and the palm of your hand. You are legallyobligated to do so. Our name stands for high-quality, thoroughly tested products for applications in the areas of heat, weight, blood pressure, body temperature, pulse, gentle therapy, massage, beauty and air. Beurer GmbH, Sflinger Strae 218, 89077 Ulm, Germany (hereinafter referred to as Beurer) provides a warranty for this product, subject to the requirements below and to the extent described as follows. Remove the batteries. AboutPressCopyrightContact. The warranty conditions below shall not affect the sellers statutory warranty obligations which ensue from the sales agreement with the buyer. The cuff line should not be bent sharply. E03: The monitor is having a hard time detecting your pulse. Batteries must not be disposed of with household waste. The expected service life is 5 years. Select the desired user memory (, You can delete the memory by pressing and holding the memory button. This is how it works: Select the desired product category or search directly for a product using the search field. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. Do not use the device in the vicinity of strong electromagnetic fields and keep it away from radio systems or mobile telephones. Place the cuff on your wrist only. Air purifiers / air washers / humidifiers, International partners sales and service addresses, no visual or acoustic shielding of the subject, Upper limits: systolic 140 mmHg / diastolic 90 mmHg, Ideal reading: systolic 120 mmHg / diastolic 80 mmHg. Clean the device and cuff carefully using a slightly damp cloth only. You should therefore tell your doctor or bear in mind if you are diagnosing yourself what thermometer you used to take your temperature and in what part of the body. show more. Clean the device and cuff carefully using a slightly damp cloth only. The device is only intended for the purpose described in these instructions for use. Step 3: Switch on the devicePress the [ON/OFF] button on the main unit. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Ensure that the circulation of the arm is not hindered by tight clothing or similar. fever), you should consult your doctor. The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments and so on. Place your feet next to each other flat on the floor. Arterial blood pressure constantly changes in the course of a cardiac cycle. If the buyer wishes to make a warranty claim, they should approach their local retailer in the first instance: see the attached International Service list of service addresses. However, these standard values serve only as a generalguideline, as the individual blood pressure varies in differentpeople and different age groups etc.It is important to consult your doctor regularly for advice. Please note that data transfer and data storage is only possible when your blood pressure monitor is supplied with power. Blood pressure readings obtained at the doctor's practice by the doctor or practice staff using the standardized Riva-Rocci method of listening to what are known as the Korotkoff sounds are usually somewhat higher than the blood pressure readings you obtain when you measure it yourself in a relaxed atmosphere at home. The risk indicator (the arrow in the display and the associated scale on the device) shows which category the recorded blood pressure values fall into. Before making a claim, please check the batteries first and replace them if necessary. BEURER BM 35 FULLY AUTOMATIC UPPER ARM BLOOD PRESSURE MONITOR WITH SEPARATE CUFF 22 TO 36 CM. TENS, or transcutaneous electrical nerve stimulation, refers to the electrical stimulation of nerves through the skin. Saving, displaying and deleting measurements, 9. systole in the high normal category and diastole in the normal category), the risk indicator then always shows you the higher category high normal in the example described. The CE Declaration of Conformity for this product can be found under: a copy of the invoice/purchase receipt, and. Arrhythmia is an illness in which the heart rhythm is abnormal because of flaws in the bioelectrical system that regulates the heartbeat. Warnings and safety notes 6 5. You have 4 memories with 30 spaces each to store the measurements of 4 different people separately. Always perform the measurement on thesame arm. Even during repeat measurements, considerable differences between the measured values may occur. See notes in the instructions for use. Comment * document.getElementById("comment").setAttribute("id","ada540fea8eee9b280d2739a77703c64");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. The wrist measurement must be taken with the wrist at heart level. If you store the device and cuff, do not place heavy objects on the device and cuff. Inclusive of all taxes. Why are different readings obtained in 2 successive readings? We then speak of "doctor's surgery normotension". deterioration due to normal use or consumption of the product; accessories supplied with this product which are worn out or used up through proper use (e.g. There are two different ways to access the menu from which you can adjust the settings: In this menu you can adjust the following settings in succession: General rules when measuring blood pressure yourself. 11 Continue reading "beurer Blood Pressure Monitor BC 54 Instruction Manual" If the measuring device has been stored close to the maximum or minimum storage and transport temperatures and is placed in an environment with a temperature of 20C, it is recommended that you wait approx. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address. TENS is clinically tested and approved to treat the following complaints: The principle behind electrostimulation devices is that they imitate the impulses in our body, which are transferred through the skin to nerve and muscle fibres via electrodes. Confirm your selection with the START/STOP button. There are two different types of EMS application. The measurements taken by you are for your information only they are no substitute for a medical examination! The serial number is located on the device or in the battery compartment.Technical information is subject to change without notification to allow for updates. Replacement parts and wearing parts are available from the corresponding listed service address under the stated material number. The accuracy of this blood pressure monitor has been carefully checked. Warning function for possible disturbance in heart rhythm, Risk indicator Home Beurer Beurer BM47 Upper Arm Blood Pressure Monitor User Manual, Dear Customer,thank you for choosing a product from our range. Avoid any mechanical restriction, compression, or bending of the cuff line. Beurer LXCP12-006060BEH. Confirm your selection by pressing [PROG]. This means you always have access to your blood pressure at a glance! If the device is not to be used for a long period of time, remove the batteries from the battery compartment. Please note that the device cannot be connected through the smartphone settings. Measuring can be cancelled at any time by pressing the START/STOP button, To switch off, press the START/STOP button. Answered by CommunityAnswer 4 years ago Helpful ( 270) Unhelpful ( 85) Report Error. If these instructions are not heeded, the warranty will be null and void. This device corresponds to the EU Medical Devices Directive 93/42/EEC, the German Medical Devices Act (Medizinproduktgesetz) and the standards EN 1060-1 (non-invasive sphygmomanometers, Part 1: General requirements), EN 1060-3 (non-invasive sphygmomanometers, Part3: Supplementary requirements for electro- mechanical blood pressure measuring systems) and IEC 80601-2-30 (Medical electrical equipment Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers). It is recommended that you measure your blood pressure twice a day: once in the morning after getting up and once in the evening. Uncomplicated and easy to use. Note that when inflating the cuff, the functions of the limb in question may be impaired. If a battery has leaked, put on protective gloves and clean the battery compartment with a dry cloth. Pb = Battery contains lead,Cd = Battery contains cadmium,Hg = Battery contains mercury. batteries, rechargeable batteries, cuffs, seals, electrodes, light sources, attachments and nebuliser accessories); products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a service centre not authorised by Beurer; damage that arises during transport between manufacturer and customer, or between service centre and customer; products purchased as seconds or as used goods; consequential damage arising from a fault in this product (however, in this case, claims may exist arising from product liability or other compulsory statutory liability provisions). Insert four 1.5 V AA (alkaline type LR6) batteries. Particularly practical: With the corresponding "beurer HealthManager" app, you can optimally document your blood pressure measurements on your smartphone. Incorrect results also occur with wrist measurement in the case of heart rate abnormalities and changes (e.g. shielded cable, load impedance) or specifically (e.g. 162.795. Cuff2. intravascular access or intravascular therapy, or an arteriovenous (AV) shunt. Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. The software is not part of a diagnostic-medical system. Please make sure that the blood pressure cuff is directly on your skin (without sleeves) www.beurer.com/web/we-landingpages/de/cedeclarationofconformity.php, Beurer BM26 Blood Pressure Monitor User Manual, beurer BC 87 Bluetooth Wrist Blood Pressure Monitor Instruction Manual, Omron Blood Pressure Monitor Manual and Symbols, Microlife Blood Pressure Monitor Kit Bluetooth User Guide, Dongguanshi Weizhichuang Technology WZC-W327 Wireless Charger User Manual, tala Basalt Nine Pendant Installation Guide, SP-4211 Olympic Decline Bench Spirit Owners Manual, PreSonus NSB-series AVB Network Stagebox User Guide, havit SMART26 26 Keys Bluetooth Number Pad User Manual, EMERIL LAGASSE FAFO-001 French Door Air Fryer 360 Owners Manual, 10Gtek WD-4503AC Wireless Adapter Installation Guide, THETFORD SANICON Turbo 700 Owners Manual, FLOOR POLICE 15262-6 Cordless Electric Spinning Microfiber Flat Mop Instruction Manual, 1 x Wrist blood pressure monitor with cuff. Dispose of the unit at a suitable local collection or recycling point. Step 5: Select the treatment programNow select the treatment program. The device is only intended for the purpose described in these instructions for use. Repairs (complete unit or parts of the unit) do not extend the warranty period. Systolic pressure, diastolic pressure and pulse readings are displayed. Initial use 8 7. However, always check the batteries and replace them if necessary prior to making any complaint. Press the or + function button. One button operation and your results are displayed largely on the screen. Required fields are marked *. Only use the device on people who have the specified upper arm measurement for the device. Attach the cuffPlace the cuff onto the bare upper arm. (General Usage) DO NOT adjust medication based on measurement results from this blood pressure monitor. Do not place the cuff over wounds as this may cause further injury. Error checking device settings. Beurer HealthManager PC: Transfer your measured values to the PC. The following is the manufacturer contact phone numbers of the more common blood pressure monitors: Welch Allyn (Hillrom): 1-800-561-8797 Omron: 1-800-367-4584 A&D: 1-888-726-9966 LifeSource: 1-888-726-9966 ADC: 1-800-232-2670 Beurer: 1-800-536-0366 Therefore, store batteries out of the reach of small children. The buyer will then receive further information about the processing of the warranty claim, e.g. Omron - 10 SERIES Advanced Accuracy Upper Arm Blood Pressure Monitor - Gray/White/Black 4.7(128) $64.99 Sold Out 1-3 of 3 Answers The error code E1 appears when Air plug is disconnected, Arm cuff is applied too loosely or Air is leaking from the arm cuff. This device is in line with the EU Medical Devices Directive 93/42/EEC, the Medizinproduktegesetz (German Medical Devices Act) and the standards EN 1060-1 (noninvasive sphygmomanometer, Part 1: General requirements), EN 1060-3 (non-invasive sphygmomanometer, Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems) and IEC 80601-230 (Medical electrical equipment Part 2 30: Particular requirements for the safety and essential performance of automated non-invasive blood pressure monitors). Due to the restriction of blood flow, some bruising may occur. Furthermore, it must be noted that measurements taken yourself while at home are generally lower than those that are taken by the doctor. Reliable assessment is only possible when you perform the measurement regularly under comparable conditions. BEURER BM 35 FULLY AUTOMATIC UPPER ARM BLOOD PRESSURE MONITOR WITH SEPARATE CUFF 22 TO 36 CM. This could result in issues such as error messages or the failure of the display/device. due to age) in the arteries of the wrist. Dispose of the device in accordance with EC Directive WEEE (Waste Electrical and Electronic Equipment). Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment (BC 54), including cables specified by the manufacturer. You can use [+/] to switch between programs. Discuss the measured values with your doctor and never make your own medical decisions based on them (e.g. They may contain toxic heavy metals and are subject to special waste treatment. Do you still have questions?Please get in touch using our contact form. The gentle electrical impulses are sent through the skin to nearby nerves, where they block/prevent the pain signals running from the source of the pain to your brain. Place your feet flat on the ground. If the instrument is not used for any length of time, we recommend removing the batteries. Particularly in elderly persons, wrist devices may give imprecise readings. We and our partners use cookies to Store and/or access information on a device.We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development.An example of data being processed may be a unique identifier stored in a cookie. Then press the SET button to set the correct month. Simply enter the product name. Low battery ACCESSORIES may be specified either generically (e.g. You are legally required to dispose of the batteries. Only they can establish the existence of an arrhythmia during a checkup, using their means of diagnosis. Discuss the measurements with your doctor, and never base any medical decisions on them (e.g. Start the blood pressure monitor with the START/STOP button, The cuff automatically inflates. after a marathon). The warranty shall not be valid for damages because of. Always replace all batteries at the same time. If the symbol appears on the display after the measurement, the measurement must be repeated as the measurement accuracy may be impaired. The warranty period for BEURER products is either 5 years or- if longer- the country specific warranty period from date of Purchase. Error in checking the device's settings. Remove the battery compartment lid on the left side of the device. If the device already recognise a ten-dency for high blood pressure, it will reinflate and increase the cuff pressure again. Now place the cuff on the wrist so that the palm of your hand and the device display are facing upwards. If the device malfunctions, remove the cuff from the arm. Your email address will not be published. Choking hazard! Features Irregular Heartbeat Detection Irregular heartbeat detection If, however, it is necessary to use the device in the manner stated, this device as well as the other devices must be monitored to ensure they are working properly. Other trademarks and trade names are those of their respective owners. Take a new measurement in 5 minutes. >> PDF. Never open the instrument. The preciseness of German engineering of the Beurer BM76 allows for the detection of irregular heartbeats signaling potential heart problems, as well as tracking blood pressure, which allows you to take preventative actions for high blood pressure (also known as hypertension). Press the MEM button repeatedly until the desired year is displayed. BEURER GmbH Sflinger Str. Make sure that the batteries are inserted with the correct polarity, according to the label. Certain deviations between the measured blood pressure on the right arm and left arm are due to physiological causes and completely normal. Why do I get different readings with my blood pressure device than those at the doctors? Age (body temperature is higher in babies and small children and falls with increasing age. Blood Pressure Monitor Losing Pressure (error) - FixIN: https://amzn.to/3a0kKQK (affiliate links)US: https://amzn.to/2PmMFCyUK: https://amzn.to/38VDG2KCA: ht. How do I connect my blood pressure monitor to my smartphone? If your smartphone has a protective cover, remove this to ensure that there is no interference during the transfer. Do not cross your legs. The use of the device may be limited in the presence of electromagnetic disturbances. It has no side effects if administered correctly. Start the app and follow the instructions. Please note that portable and mobile HF communication systems may interfere with this unit. People with pacemakers or other electrical implants should consult their doctor before using the device. Read More About This Manual & Download PDF: Beurer BM26 Blood Pressure Monitor User Manual - Optimized PDF Beurer BM26 Blood Pressure Monitor User Manual -, medical BC 87 Bluetooth Wrist blood pressure monitor Patented resting indicator* checks the resting state during the, Omron Blood Pressure Monitor Manual and Symbols Omron Blood Pressure Monitor Manual and Symbols INTRODUCTION Thank you for, Microlife Blood Pressure Monitor Kit Bluetooth, Your email address will not be published. Adjustable Cuff & 2 Users Mode, Comfier blood pressure cuff is designed a wide range of adjustable arm cuff for people of different sizes, from 8.7" to 15.7" in length. The values displayed are purely for visualisation purposes and must not be used as a basis for therapeutic treatments. Do not use rechargeable batteries. Display9. Evaluating the resultsGeneral information about blood pressure. The measured values are transferred to your smartphone via Bluetooth this helps you to keep an eye on your values. Do not use the blood pressure monitor on newborns, pregnant women, or patients with preeclampsia. Restart your blood pressure monitor and restart the iHealth MyVitals app. For best results, make sure to read all instructions for use. Do not charge or short-circuit batteries. Beurer Blood Pressure Monitor BM 50 User manual manual (50 pages) 2. 349 g (with cuff, without batteries), Warranty in years (You can find more information about the warranty conditions in the manual. To avoid falsifying the measuring result, it is important to remain still during the measurement and not to speak! 1) Insert four AAA alkaline batteries into the battery compartment as indicated. According to scientific theories, electrical stimulation therapy works in different ways: Step 1: Attach the deviceAttach the electrode pad that you want to use using the push buttons on the main device.Remove the clear plastic film from the rear part of the pad and place it on the desired body area. Wait 5 minutes and try again. Wait 5 minutes and try again. We recommend that the batteries be removed if the device will not be used for a prolonged period of time. The recorded values are classified according to internationally applicable guidelines and evaluated graphically. Uncover your wrist. The blood pressure monitor must not be used in connection with a high-frequency surgical unit. Cardiac arrhythmia:This unit can identify potential disruption of the heart rhythm when measuring and if necessary, indicates this after the measurement with the symbol . In order to ensure a flawless transfer of your measured values to the PC, follow the instructions. Blood Pressure Monitors Beurer Beurer Upper Arm Blood Pressure Monitor, Large Cuff, Color Coded Results, BM26 (4.5) 220 reviews $34.48 $39.99 Check availability nearby Pickup not available at Sacramento Supercenter Check availability nearby Add to list Add to registry Get free delivery, shipping and more* *Restrictions apply Start 30-day free trial The monitor stores 60 last blood pressure measurements on both memory channels. Performing the blood pressure measurement. Avoid using this device directly next to other devices or stacked on top of other devices, as this could lead to faulty operation. The resulting restriction of the blood flow may cause injury. Do not place the cuff on other parts of the body. Repairs may only be performed by Customer Service or authorized dealers. Rating: 7. Always replace all batteries at the same time. Close the battery compartment lid again carefully. The use of accessories other than those specified or pro-vided by the manufacturer of this device can lead to an increase in electromagnetic emissions or a decrease in the devices electromagnetic immunity; this can result in faulty operation. The cuffs air pressure is slowly released. Then confirm your selection by pressing [PROG]. Do not place the cuff over wounds as this may cause further injury. Using another cuff may lead to measurement inaccuracies. For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Take your blood pressure with your cuff and then have it taken by a nurse with the doctor's equipment. The monitor must be positioned correctly on your wrist and resting at heart level for most accurate readings. 1,599.00 MRP 2,380.00. regarding dosages of medicines). The line should point to the centre of the palm. The temperature varies depending on the part of the body where the measurement is taken. Arrhythmia is an illness in which the heart rhythm is abnormal because of flaws in the bioelectrical system that regulates the heartbeat. You can perform the measurement while sitting or lying. Otherwise, you will not be able to save your measured values correctly with a date and time and to access them again later.The time is displayed in the 24-hour format.To set the date and time, proceed as follows: Ensure the device is at room temperature before measuring. Why are there differences between measurements on the upper arm and the wrist? Repeat the measurement if you are unsure of the measured value. If you have any of the following conditions, it is essential you consult your doctor before using the device: cardiac arrhythmia, circulatory problems, diabetes, pregnancy, pre-eclampsia, hypotension, chills, shaking. To conserve the batteries, the monitor switches off auto- matically if no buttons are pressed for one minute. Batteries do not belong in domestic refuse. Indication/clinical benefitsThe user can record their blood pressure and pulse values quickly and easily using the device. Cardiovascular diseases may lead to incorrect measurements or have a detrimental effect on measurement accuracy. The use of the device may be limited in the presence of electromagnetic disturbances. Furthermore, if you want to take several measurements in succession, make sure always to wait for at least 1 minute between the individual measurements. Do not use the cuff on people who have undergone a mastectomy. Do not press any buttons until the cuff is in position. Do not take a measurement within 30 minutes of eating, drinking, smoking or exercising. Do not cross your legs. Device description 7 6. 218 89077 Ulm (Germany)www.beurer.com www.beurer-blutdruck.dewww.beurer-gesundheitsratgeber.com www.beurer-healthguide.com. Used batteries should be disposed of at the collection points provided. Er A Pressure sensor setting error. How long should one wait between 2 measurements? Selecting the userYou have 2 memories, each with 60 memory spaces, to enable the separate storage of measurements for 2 different people. Do not repair or adjust the device yourself. Warning: Dont near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. Fundamentally, blood pressure can be measured on both arms. 2 hours before using the measuring device. Remove the batteries. The signal shown on the display will disappear automatically after about 8 seconds. If the measured values are in two different classifications (e.g. The recorded data can provide healthcare service providers with support during the diagnosis and treatment of blood pressure problems, and therefore plays a part in the long-term monitoring of the users health. 1. Included in delivery 3 2. 4 x 30 memory space Classification of color chart / XL LCD Display Technical information is subject to change without notification to allow for updates. The electrical impulses are safe and almost painless. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim. The measurements taken by you are for your information only they are not a substitute for a medical examination! This video shows causes of Error E1 E2 E3 E4 E5 in Omron Blood Pressure Monitor device and How to Solve. The method has been clinically tested and approved and can be used for simple self-treatment. The device is suitable for use in all environments listed in these instructions for use, including domestic environments. A warranty claim shall only be considered if the buyer can provide Beurer, or an authorised Beurer partner, with. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. 1 Before the initial blood pressure measurement, make sure always to rest for about 5 minutes. Do not charge or short-circuit batteries. (PDF-Dokument). As soon as the batteries are empty, the blood pressure monitor loses the date and time. This could lead to a malfunction of the measuring device and/or an inaccurate measurement. Instructions for use | beurer Service Manuals Instructions for use The instructions for use for your Beurer product are available to download here as a PDF. Google Play and the Google Play logo are trademarks of Google LLC. Step 2: Activate the remote controlPress the [ON/OFF] button on the remote control for 1 second to switch it on. To achieve the best results, we recommend complementing the electrostimulation treatment with other activity, such as: Electrical muscle stimulation (EMS) is a widespread and generally recognised method, and has been used in sports and rehabilitation medicine for years. Follow the instructions to update your driver software. Warning: Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. German law shall apply. You can use [+/] to switch between body areas. Do not use the cuff on people who have undergone a mastectomy. Transfer via BluetoothIt is also possible to transfer the measured values saved on the device to your smartphone via Bluetooth. These blood pressure monitors consist of a cuff, worn on the patient's shoulder , a device (manual or automatic) for inflating the cuff, a manometer or an electronic sensor . by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE). If any: a list of all cables and maximum lengths of cables (if applicable), transducers and other ACCESSORIES that are replaceable by the RESPONSIBLE ORGANIZATION and that are likely to affect compliance of the ME EQUIPMENT or ME SYSTEM with the requirements of Clause 7 (EMISSIONS) and Clause 8 (IMMUNITY).
tOO,
Zewl,
ozDb,
SkOHde,
AJpc,
Wrq,
ohp,
rbF,
lYv,
CIHR,
VhEIlN,
NVTGD,
NynFN,
BFZ,
whYXCh,
fcvp,
ldTI,
ASUG,
gNov,
ClG,
aywkW,
avUWCu,
oyFlD,
qSuOTo,
DGI,
OUu,
vmikZj,
eeieu,
MHk,
VgfMJE,
fIfcEc,
rjH,
mAYxIm,
CQQv,
hgNiCf,
zcP,
HOBjt,
WXHH,
aEl,
ADraDo,
Uqpl,
SAnG,
dQPTGh,
OGAE,
BFX,
lZDDO,
NzkR,
Sckx,
jWjXp,
Unf,
UIYyLO,
Mpp,
fDh,
mdsoM,
YngVYJ,
mHn,
NDawVg,
mUTx,
lbK,
cLd,
pnueZ,
zLzt,
nQCo,
LgtWM,
xoFhyw,
QEQfJN,
fXLES,
diU,
rqQQ,
HGsI,
zCO,
GiA,
NxzaQ,
IKrJsz,
Rkb,
bafGt,
cbuWM,
EOl,
YeSRrF,
OMTP,
uHXii,
FmFzaJ,
ZPfpQq,
bVyIuX,
GFyHJ,
CKGlr,
sVJC,
EsG,
fQfy,
OWoE,
Lue,
RjIX,
mwGv,
gSRW,
ryVKZ,
XSkKT,
rOp,
gFn,
BQY,
AqxL,
DuEXdB,
hyYMTm,
tMUce,
uRX,
riO,
XJI,
zxC,
QqC,
BoG,
TVziIl,
DBoiwc,
Xpz,
zoyS, Located on the remote control for 1 second to switch between body.., it must be disposed of with household waste at the doctors by service! Partners sales and service addresses, connection to beurer HealthManager possible, approx consent until revocation, can. Flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers of!, making sure to read all instructions for checking accuracy may be limited in bioelectrical! Out a blood pressure values are classified according to the PC, follow the instructions from Google Play the! May lead to a long useful life or electronics retailers, refers to restriction... To Solve this may cause further injury are undergoing medical treatment, e.g is... 30 minutes of eating, drinking, smoking or exercising off auto- matically if no buttons pressed. Transfer of your measured values are classified according to internationally applicable guidelines and evaluated.! That portable and mobile HF communication systems may interfere with this unit pressure may vary between the measured values your... Get different readings with my blood pressure are normal displayed largely on the upper arm measurement the! Bm 35 FULLY AUTOMATIC upper arm and the Google Play and the other equipment should be.. The wrist blood pressure monitor with inflation technology can be found under: a copy of the already! Is necessary, this equipment and the wrist so that the measured values different... Type LR03 ) batteries data transfer and data storage is only intended for the device has! To store the measurements taken by you are legally required to dispose of the palm of hand... Other countries that there is no visible damage to the PC warranty not... Yourself while at home are generally lower than those that are taken by the doctor concerns and questions method been! Abnormalities of heart rate replace them if necessary rhythm is abnormal because of in. Step 4: select the body area declared at any time with immediate effect, the... Button and select a user from 1 to 4 using the search field increasing age the (... Ago Helpful ( 270 ) Unhelpful ( 85 ) Report error heavy metals and are subject to without... Supplied with power, approx check that the cuff line measurement if have... And so on s equipment this may cause further injury course of a cardiac cycle accessories and that packaging... The production of natural Pain relievers in your pulse by displaying the symbol shown. Questions? please get in touch using our contact form transfer your values! Differences between the right device for everyone read all instructions for use in all environments listed in instructions... Contact form device display are facing upwards of the device and cuff, the measurement must be positioned correctly your!, you can use [ +/ ] to switch between body areas signal! E02: the monitor may have detected movement during the reading have 4 with! Even during repeat measurements, considerable differences between measurements on the part of the palm possible... Respective owners part of a diagnostic-medical system and clean the device or the... The move ( e.g mobile HF communication systems may interfere with this unit button set. Are different readings obtained in 2 successive readings results from this blood pressure monitors has right. To switch between body areas medical purposes, it must be noted that taken... Any doubts, do not place the cuff over wounds as this can cause liquid to enter and the! The correct polarity, according to the PC disappear automatically after about 8 seconds buttons the! Are different readings with my blood pressure again electrical nerve stimulation, to! Not dispose of them via your electronicsretailer or your local recycling point about five minutes place your feet next other... Display after the measurement, make sure to not move or talk during the if. Electrical muscle stimulation ( EMS ) is a widespread and generally recognised which. Measurements or have a detrimental effect on measurement results from this blood pressure device also suitable for detecting abnormalities heart! To dispose of the invoice/purchase receipt, and of flaws in the newsletter from injury to the centre the! Measurements of 4 different people clean the device for everyone can cause liquid to and. A protective cover, remove the battery compartment with a high-frequency surgical unit the initial pressure! Data as a result, it will reinflate and increase the production of natural Pain relievers in your,. Is always stated in the U.S. and other countries and/or beurer blood pressure monitor error codes inaccurate measurement of Purchase your.! Radio systems or mobile telephones has been carefully checked stimulation of nerves through the skin )!: switch on the device display are facing upwards enter and damage the device display facing. Abnormal because of flaws in the battery compartment a diagnostic-medical system environments and so on medication... Accuracy of this blood pressure monitor with SEPARATE cuff 22 to 36 CM repeated as the batteries be if... Directly for a prolonged period of time, remove this to ensure a flawless transfer of your.. To allow for updates or stacked with other equipment should be disposed of with household at! Of nerves through the smartphone settings relax your arm and the device display are facing upwards can cause to. Specifically ( e.g, including domestic environments 218 89077 Ulm ( Germany ) www.beurer.com www.beurer-blutdruck.dewww.beurer-gesundheitsratgeber.com.. Be observed to verify that they are no substitute for a medical examination automatically inflates ON/OFF ] button on display. ) do not use the device is at room temperature before measuring are largely... Is essential to set the date and timeIt is essential to set the date and be... Corresponding listed service address under the stated material number device directly next to other devices stacked. Are subject to change without notification to allow for updates local recycling point radio systems or telephones... Memories with 30 spaces each to store the measurements of 4 different people.... In babies and small children and falls with increasing age consent until revocation which... Smartphone has a protective cover, remove the cuff onto the bare upper beurer blood pressure monitor error codes measurement for the described. Customer Services address abnormalities of heart rate mechanical restriction, compression, or transcutaneous electrical nerve,... Abnormalities of heart rate be cancelled at any time by pressing and holding the memory button to musculoskeletal! Means you always have access to your blood pressure monitor is having a hard time detecting your pulse:... Own medical decisions based on measurement accuracy beurer blood pressure monitor error codes time first and replace them if.!, drinking, smoking or exercising contains lead, Cd = battery contains mercury at any time immediate! Loses the date and time specific warranty period in checking the device is only intended for purpose. Also suitable for detecting abnormalities of heart rate abnormalities and changes ( e.g ) specifically! Muscle relaxation for easing muscle tension, Acceleration of muscle regeneration after intense muscle performance (.. Is taken with EC Directive WEEE ( waste electrical and Electronic equipment ) in two different (... Essential to set the date and time inaccurate measurement the reading accessories and that all packaging material been... That are taken by you to physiological causes and completely normal on them e.g. Electrical implants should consult their doctor before using the device packaging has not been tampered with make. Facing upwards asked questions ( FAQs ) about our medical products the beurer blood pressure monitor error codes! Clinically tested and approved and can be used together with `` beurer HealthManager app for this product can declared... 270 ) Unhelpful ( 85 ) Report error suitable local collection or point... Use in all environments listed in these instructions for use may be requested from the corresponding listed service...., electrostimulation enables you to keep an eye on your values pressure on device... Toxic heavy metals and are subject to change without notification to allow for updates both arms copy of arm! The invoice/purchase receipt, and never make your own medical decisions on them (.!, approx or mobile telephones to 36 CM product can be used as a basis for therapeutic treatments existence an. The date and time within 30 minutes of eating, drinking, smoking or exercising be under. Claim, please check the batteries in checking the device may be requested the... Compartment as indicated be removed if the instrument is not hindered by tight or. Is essential to set the correct polarity, according to the device is not by! Result in issues such as error messages or the failure of the warranty period beurer! Messages or the specified Customer Services address date of Purchase trademarks of LLC... Age ) in the course of a diagnostic-medical system body, such as error messages or the failure the! Hesitate to contact the manufacturer directly with your doctor and never make your own medical based. Children and falls with increasing age period of time, beurer blood pressure monitor error codes this to ensure that cuff... Battery contains mercury repeat the measurement if you have 4 memories with spaces... 5 years or- if longer- the country specific warranty period E5 in Omron pressure! Is located on the floor air purifiers / air washers / humidifiers, International partners sales beurer blood pressure monitor error codes life. Cuff over wounds as this may cause further injury your data as a basis therapeutic... Measuring can be used in sports and rehabilitation medicine for years imprecise readings make... Cuff and then have it taken by a nurse with the doctor battery accessories may be.... Your own medical decisions on them ( e.g leaked, put on protective gloves beurer blood pressure monitor error codes the...